ABX Double Blind Test Results: First Order Filters


ABX Home ABX Hardware ABX Data ABX Literature

SMWTMS ABX Test Results

One Pole Filters vs. wireResultCorrectp less thanListeners
High Pass -3 dB @ 40 Hz. Different28 / 32 = 88%0.00052
Low Pass -3 dB @ 13.5 kHz. (pink noise) Different 64 / 64 = 100%0.00054
Low Pass -3 dB @ 13.5 kHz. (music) Different 30 / 42 = 93%0.0005 5

The tests of single pole filters were done on a single AR-5 speaker in mono.

Different The different symbol means it is unlikely the percent correct score occurred by chance and thus the null hypothesis was disproven, which substantiates a real difference in sound quality.
Same The same symbol means that it is likely the correct score occurred by chance, the null hypothesis is not rejected, which means no difference was found. It does remain possible a difference may be substantianted with further testing.

ABX Home ABX Hardware ABX Data ABX Literature
Send questions or comments on the ABX Web Page to David Carlstrom.

Web Page Created by David Carlstrom. Last Modified: 1/26/2011